Automated Building Reporting

Admin

Internal Walls Defects - Buttons

New Button
Label Report Text Sort Order Actions
Rising Damp - DPC Not Effective High damp meter readings were recorded to the ground floor walls, likely caused by the absence or failure of an effective damp-proof course. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works 0 Edit
Rising Damp - High Ground Level High damp meter readings were recorded to the ground floor walls, which appear to have been caused by high external ground levels. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works 1 Edit
Rising Damp - Render Bridging High damp meter readings were recorded to the ground floor walls, which appear to have been caused by external render bridging the damp-proof course. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works 2 Edit
Rising Damp - Salts High damp meter readings were recorded to the ground floor walls, which appear to have been caused by salt-contaminated plaster. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works 3 Edit
Rising Damp - Failed DPC High damp meter readings were recorded to the ground floor walls, which appear to have been caused by failure of the damp-proof course. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works. There is also a risk of associated decay to adjacent timbers, which should be inspected and treated or repaired as necessary 4 Edit
Penetrating Damp - Weathered Masonry High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of weathered masonry. Repairs and improvements are required to prevent further moisture ingress 5 Edit
Penetrating Damp - Defective Render High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of defective render. Repairs and improvements are required to prevent further moisture ingress 6 Edit
Penetrating Damp - Defective Rainwater Fittings High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of defective rainwater fittings. Repairs and improvements are required to prevent further moisture ingress 7 Edit
Penetrating Damp - Inadequate Window Sills High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of inadequate window sills. Repairs and improvements are required to prevent further moisture ingress 8 Edit
Condensation - Kitchen High damp meter readings, along with mould growth, were noted in the kitchen. This is caused by condensation. The affected areas should be cleaned, and the finishes made good. Heating and ventilation should be improved to help reduce the likelihood of recurrence 9 Edit
Condensation - Bathroom High damp meter readings, along with mould growth, were noted in the bathroom. This is caused by condensation. The affected areas should be cleaned, and the finishes made good. Heating and ventilation should be improved to help reduce the likelihood of recurrence 10 Edit
Woodworm Wood-boring beetle activity was observed in the wall timbers. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a Property Care Association (PCA) member is recommended 11 Edit
Possible Structural Movement - Ground Floor Cracking was noted to the ground floor, which may be indicative of structural movement. Further investigation is required by a Chartered Structural Engineer to determine the cause and necessary remedial works 12 Edit
Possible Structural Movement - First Floor Cracking was noted to the first floor, which may be indicative of structural movement. Further investigation is required by a Chartered Structural Engineer to determine the cause and necessary remedial works 13 Edit
Walls Removed - Poorly Supported - Cracking Internal alterations have been carried out to remove walls. The support provided may be inadequate, as evidenced by cracking. Further investigation is required by a Chartered Structural Engineer to assess adequacy and recommend any necessary remedial works 14 Edit
Walls Removed - Poorly Supported - Distortion Internal alterations have been carried out to remove walls. The support provided may be inadequate, as evidenced by distortion. Further investigation is required by a Chartered Structural Engineer to assess adequacy and recommend any necessary remedial works 15 Edit
Plaster - Loose Sections of plaster are loose and require replastering to restore the finish 16 Edit
Plaster - Cracked Sections of plaster are cracked and require replastering to restore the finish 17 Edit
Artex Textured finishes may contain asbestos and can release fibres if disturbed. A qualified specialist should complete a risk assessment before any work is undertaken 18 Edit
Minor Mould - Kitchen Minor mould growth was noted to the kitchen walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 19 Edit
Minor Mould - Bathroom Minor mould growth was noted to the bathroom walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 20 Edit
Minor Mould - Bedroom Minor mould growth was noted to the bedroom walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 21 Edit
Minor Mould - General Minor mould growth was noted to the walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 22 Edit
Localised Damp Localised damp readings were noted to the ground floor walls; repairs are needed to resolve the issue 23 Edit
Minor Plaster Defects - Cracked Cracking was noted to sections of plaster; repairs are required 24 Edit
Minor Plaster - Loose Some plaster is loose and needs to be repaired 25 Edit
Minor Plaster - Water Stained Sections of plaster are water stained and require repair and redecoration once the source of moisture has been resolved 26 Edit
Minor Plaster - Damaged Some plaster is damaged and needs to be repaired 27 Edit
Decorations Poor Internal decorations are in poor condition and require improvement. Some minor plaster repairs may be needed where fittings are removed 28 Edit
Defective Tiling - Bathroom The tiling in the bathroom is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance 29 Edit
Defective Tiling - Shower Room The tiling in the shower room is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance 30 Edit
Defective Tiling - Kitchen The tiling in the kitchen is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance 31 Edit
Defective Tiling - WC The tiling in the WC is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance 32 Edit
Back to Sections