Automated Building Reporting
| Label | Report Text | Sort Order | Actions |
|---|---|---|---|
| Unsafe Glazing | Some door glazing lacks markings confirming safety glass. To minimise injury risk, the glass should be replaced with toughened or laminated glass | 0 | Edit |
| Staircase - Steep | The staircase is excessively steep and poses a safety hazard. Urgent remedial action is recommended | 1 | Edit |
| Staircase - Missing Handrail | The staircase lacks a handrail and poses a safety hazard. A compliant handrail should be installed urgently | 2 | Edit |
| Staircase - Loose Handrail | The handrail to the staircase is loose and poses a safety hazard. It should be repaired or replaced urgently | 3 | Edit |
| Open Riser Stairs | The open staircase poses a safety hazard, particularly to small children. The open risers should be enclosed to improve safety | 4 | Edit |
| Gaps in Balustrade - Stairs | The stair guarding contains gaps wide enough to pose a risk to children. Safety improvements are needed | 5 | Edit |
| Woodworm - Skirting Boards | Wood-boring beetle activity was observed in the skirting boards. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a PCA member is recommended | 6 | Edit |
| Woodworm - Staircase | Wood-boring beetle activity was observed in the staircase timbers. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a PCA member is recommended | 7 | Edit |
| Timber Decay - Staircase | Rot was noted to the staircase; replacement is required | 8 | Edit |
| Timber Decay - Skirting Boards | Rot was noted to the skirting boards; replacement is required | 9 | Edit |
| Timber Decay - Window Sills | Rot was noted to the window sills; replacement is required | 10 | Edit |
| Timber Decay - Door Surrounds | Rot was noted to the door surrounds; replacement is required | 11 | Edit |
| Asbestos | Some internal joinery may contain asbestos. A qualified specialist must carry out a risk assessment before any work is undertaken | 12 | Edit |
| Multiple Floors - Self Closers | As the property extends over several floors, doors to the escape route should be fire-resisting. Some self-closers are defective, creating a safety risk; remedial works are needed | 13 | Edit |
| Multiple Floors - Smoke Seals | As the property extends over several floors, doors to the escape route should be fire-resisting. Some smoke seals are defective, posing a safety risk; remedial works are required | 14 | Edit |
| Skirting Boards - Damaged | Damaged skirting boards were noted; repair or replacement is required | 15 | Edit |
| Door Surrounds - Damaged | Damaged door surrounds were noted; repair or replacement is required | 16 | Edit |
| Skirting Boards - Poorly Fitted | Poorly fitting skirting boards were noted; repair or replacement is required | 17 | Edit |
| Door Surrounds - Poorly Fitting | Poorly fitting door surrounds were noted; repair or replacement is required | 18 | Edit |
| Doors - Missing | Missing doors were noted; replacement is required | 19 | Edit |
| Doors - Adjust | Several doors need adjustment to operate correctly | 20 | Edit |
| Decorations | Some internal joinery items are in need of decoration | 21 | Edit |
| Creaking Staircase | The stairs creak when walked on — you may want to have the treads repaired or tightened | 22 | Edit |