Automated Building Reporting

Admin

Ceilings Defects - Buttons

New Button
Label Report Text Sort Order Actions
Ceiling Poor The ceiling is in poor condition and requires repair or replacement to restore its appearance and integrity 0 Edit
Ceilings Poor (Multiple) The ceilings are in poor condition and require repair or replacement to restore their appearance and integrity 1 Edit
Ceiling Sagging The ceiling is sagging and requires repair or replacement to prevent potential collapse and ensure safety 2 Edit
Ceilings Sagging (Multiple) The ceilings are sagging and require repair or replacement to prevent potential collapse and ensure safety 3 Edit
Ceiling Water Damaged The ceiling is water damaged and requires repair or replacement to prevent potential collapse and ensure safety 4 Edit
Ceilings (Multiple) Water Damaged The ceilings are water damaged and requires repair or replacement to prevent potential collapse and ensure safety 5 Edit
Damaged Artex The textured finishes are defective. These types of finishes may contain asbestos. Before carrying out any work that may disturb asbestos-containing materials, a risk assessment should be undertaken by a suitably qualified specialist 6 Edit
Polystyrene Tiles Polystyrene ceiling finishes are a fire risk and should be removed. The plaster underneath may require repair once exposed 7 Edit
Damp from Sanitary Leak Damp staining, likely from leaking sanitary fittings, was observed. Repairs are needed, and nearby timbers should be checked for decay 8 Edit
Damp from Valley Gutter Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the valley gutter. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary 9 Edit
Damp from Rainwater Fittings Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the rainwater fittings. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary 10 Edit
Damp from Roof Coverings Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the roof coverings. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary 11 Edit
Damp from Defective Flashings Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from defective flashings. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary 12 Edit
Damp from Chimney Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the chimney. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary 13 Edit
Mould to Bathroom Ceiling Mould growth was noted to the bathroom ceiling, caused by condensation. The affected areas should be cleaned and redecorated as necessary. Heating and ventilation should be improved to help reduce the likelihood of recurrence 14 Edit
Woodworm to Timbers Wood-boring beetle activity was observed in the exposed beams/timber cladding. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a Property Care Association (PCA) member is recommended 15 Edit
Ceiling Cracked The ceiling is cracked, and localised repair is required to restore the finish 16 Edit
Ceilings Cracked (Multiple) The ceilings are cracked, and localised repairs are required to restore the finishes 17 Edit
Ceiling Water Stained The ceiling is water stained, and localised repair and redecoration are required 18 Edit
Ceilings (Multiple) Water Stained The ceilings are water stained, and localised repair and redecoration are required 19 Edit
Ceiling Damaged The ceiling is damaged, and localised repair is required to restore the finish 20 Edit
Ceilings (Multiple) Damaged The ceilings are damaged, and localised repairs are required to restore the finishes 21 Edit
Coving Poor The coving is defective in places and requires repair or replacement to restore its appearance 22 Edit
Damp Staining - Roof Leak The ceiling has been affected by damp resulting from a roof leak. The damaged areas require repair once the source of the leak has been resolved 23 Edit
Damp Staining - Plumbing Leak The ceiling has been affected by damp resulting from a plumbing leak. The damaged areas require repair once the leak has been rectified 24 Edit
Damp Staining (Multiple) - Roof Leaks A number of ceilings have been affected by damp resulting from a plumbing leak. The damaged areas require repair once the leak has been rectified 25 Edit
Damp Staining - Plumbing Leaks (Multiple) A number of ceilings have been affected by damp resulting from a plumbing leak. The damaged areas require repair once the source of the leak has been rectified 26 Edit
Damp Staining - Floor Above The ceiling has been affected by damp as a result of a leak from the floor above. The damaged areas require repair once the source of the leak has been rectified 27 Edit
Damp Staining Floor Above (Multiple) The ceilings have been affected by damp as a result of a leak from the floor above. The damaged areas require repair once the source of the leak has been rectified 28 Edit
Minor Mould - Bathroom Ceiling Mould growth was noted to the bathroom ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 29 Edit
Minor Mould - Ensuite Ceiling Mould growth was noted to the ensuite ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 30 Edit
Minor Mould - Kitchen Mould growth was noted to the kitchen ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 31 Edit
Minor Mould - Utility Room Mould growth was noted to the utility room ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 32 Edit
Minor Mould Ceilings (Multiple) Mould growth was noted to some ceilings, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence 33 Edit