Automated Building Reporting

Admin

Roof Space Defects - Buttons

New Button
Label Report Text Sort Order Actions
Not Strengthened - Main Roof The main roof covering has been replaced with heavier tiles, but the roof structure has not been adequately strengthened to support the additional load. Structural improvements are now required. Recovering the roof would have required Building Regulation approval, and you should confirm that this approval was obtained 0 Edit
Not Strengthened - Extension The extension roof covering has been replaced with heavier tiles, but the roof structure has not been adequately strengthened to support the additional load. Structural improvements are now required. Recovering the roof would have required Building Regulation approval, and you should confirm that this approval was obtained 1 Edit
Defective Structure - Undersized Timbers The roof structure is defective, with supporting timbers that are undersized. Repair and upgrading are now required to ensure structural stability and safety 2 Edit
Defective Structure - Timbers Cut The roof structure is defective, as some supporting timbers have been cut through. Repair and upgrading are now required to restore structural integrity and ensure safety 3 Edit
Defective Structure - Poorly Supported The roof structure is defective, with supporting timbers poorly supported on the walls. Repair and upgrading are now required to ensure adequate structural stability 4 Edit
Building Paper The main roof has been lined with building paper that now requires replacement. This material may contain asbestos, and if disturbed, harmful fibres could be released into the property. Before carrying out any work on suspected asbestos-containing materials, a risk assessment should be undertaken by a suitably qualified specialist 5 Edit
Spray Foam The underside of the roof has been sprayed with foam insulation. This increases the risk of concealed timber decay and may adversely affect the future saleability of the property. Further investigation is required to determine the extent of work necessary to remove the material and assess any associated damage 6 Edit
Damaged Felt - Main Roof The main roof lining is in poor condition and requires repair or replacement. Should replacement be necessary, the roof covering will need to be removed, which is likely to be costly 7 Edit
Damaged Felt - Extension Roof The extension roof lining is in poor condition and requires repair or replacement. Should replacement be necessary, the roof covering will need to be removed, which is likely to be costly 8 Edit
Woodworm - Main Roof Wood-boring beetle activity was noted in the main roof space. Confirm whether treatment has been carried out under guarantee; if not, a Property Care Association (PCA) member should undertake treatment 9 Edit
Woodworm - Extension Roof Wood-boring beetle activity was noted in the extension roof space. Confirm whether treatment has been carried out under guarantee; if not, a Property Care Association (PCA) member should undertake treatment 10 Edit
Timber Decay - Dry Rot Some of the roof timbers have been affected by dry rot and require repair by a suitably qualified specialist to prevent further deterioration 11 Edit
Timber Decay - Wet Rot Some of the roof timbers have been affected by wet rot and require repair by a suitably qualified specialist to prevent further deterioration 12 Edit
Party Wall Missing The party wall is missing and should be constructed up to the underside of the roof covering to provide adequate separation and fire protection between the properties 13 Edit
Party Walls Incomplete The party wall is incomplete and contains holes and gaps that should be properly sealed to improve fire resistance and security between the properties 14 Edit
Loft Boarding - Loose Some of the boards laid down for storage and access purposes are loosely supported, and improvements are required to ensure they are safe and adequately secured 15 Edit
Significant Rot - Roof Structure There is significant timber decay within the roof structure, and repair or replacement of the affected elements is required to ensure structural integrity 16 Edit
Significant Rot - Rafters There is significant timber decay to the rafters, and repair or replacement of the affected sections is required to maintain structural stability 17 Edit
Significant Rot - Purlins There is significant timber decay to the purlins, and repair or replacement of the affected sections is required to maintain structural integrity 18 Edit
Significant Rot - Under Valley Gutters There is significant timber decay to the underside of the valley gutters, and repair or replacement of the affected timbers is required to prevent further deterioration 19 Edit
Significant Rot - Timbers Near Stack There is significant timber decay to the timbers adjacent to the chimney stack, and repair or replacement of the affected sections is required to maintain structural integrity 20 Edit
Leakage - Flashings Chimney flashings are leaking; repair is required, and nearby timbers should be inspected for decay 21 Edit
Leakage - Roof Abutments Roof abutments are leaking; repair is required, and surrounding timbers should be checked for decay 22 Edit
Masonry - Chimney Damp Dampness was noted to the chimney in the roof space; repairs are needed to prevent ongoing moisture ingress 23 Edit
Masonry - Party Wall Damp The party wall within the roof space is damp and requires repair to prevent further moisture penetration and deterioration 24 Edit
Masonry - Gable Wall Damp The gable wall within the roof space is damp and requires repair to prevent further moisture ingress and deterioration 25 Edit
Masonry - Chimney Deteriorating The chimney within the roof space is deteriorating and requires repair to prevent further decay and potential instability 26 Edit
Masonry - Party Wall Deteriorating The party wall within the roof space is deteriorating and requires repair to prevent further decay and potential structural issues 27 Edit
Masonry - Gable Wall Deteriorating The gable wall within the roof space is deteriorating and requires repair to prevent further decay and potential structural damage 28 Edit
Moisture - Lack of Ventilation Excessive moisture was noted in the roof space, caused by poor ventilation. Improvements are needed to prevent timber decay 29 Edit
Moisture - Inadequate Insulation Excessive moisture was noted in the roof space, likely caused by insufficient insulation. Improvements are needed to prevent timber decay 30 Edit
Moisture - Extractor Fan In Roof Space There is excessive moisture within the roof space caused by an extractor fan venting directly into it. This increases the risk of timber decay, and repairs or improvements are required to ensure the fan is properly ducted to the outside 31 Edit
Vermiculite Loose insulation material, believed to be vermiculite, was noted within the roof space. This material may be contaminated with asbestos fibres and therefore presents a potential health and safety risk. Further investigation and testing should be carried out by a specialist asbestos contractor 32 Edit
Leaking Plumbing Staining and rot were noted to the timbers, caused by leakage from the central heating installation. Repairs are required to address the leak and replace or treat the affected timbers as necessary 33 Edit
Diagonal Bracing There is insufficient diagonal bracing between the trusses, and improvements are required to ensure adequate structural stability 34 Edit
Missing End Strapping The end strapping between the roof structure and the gable wall is missing, and improvements are required to ensure adequate restraint and structural stability 35 Edit
Straps There is no end strapping between the roof structure and the walls, and improvements are required to provide adequate restraint and structural stability 36 Edit
Underfelt - Patch Repair The roof underlining is damaged in places, and patch repairs are required to maintain weather protection 37 Edit
Vermin Evidence of vermin activity was noted in the roof space; pest control treatment is recommended to prevent further infestation 38 Edit
Felt Under Rafters - Ventilation Felt beneath the rafters is blocking adequate ventilation to the roof space; removal is recommended 39 Edit
Plastic Sheeting Under Rafters - Ventilation The installation of plastic sheeting beneath the rafters is obstructing roof ventilation; removal is recommended 40 Edit
Timber Boarding - Ventilation The installation of timber boarding below the rafters is obstructing roof ventilation; removal is recommended 41 Edit
Insulation over Lights Insulation has been placed over recessed light fittings, increasing the risk of overheating. Improvements are needed to ensure fire safety 42 Edit
Insufficient Insulation The insulation present is insufficient by modern standards and should be enhanced to improve efficiency 43 Edit
Ventilation Ventilation within the roof space is inadequate; enhancement is needed to reduce the risk of condensation forming 44 Edit
Back to Sections