| Label | Report Text | Sort Order | Actions |
|---|---|---|---|
| Render Cracked Repair or Replace | Cracks are present in the render finishes. Re-rendering or substantial patch repairs are necessary to prevent moisture ingress and additional deterioration | 0 | Edit |
| Render Hollow Repair or Replace | Areas of the render are hollow. Re-rendering or significant patch repairs are recommended to prevent moisture ingress and ongoing deterioration | 1 | Edit |
| Render Loose Repair or Replace | Sections of the render are loose. Re-rendering or significant patch repairs are recommended to prevent moisture penetration and progressive deterioration | 2 | Edit |
| Pointing Deteriorated | The existing mortar pointing has deteriorated. Re-pointing is necessary to restore integrity and weather resistance | 3 | Edit |
| Coping Stones Loose | The coping stones on the parapet walls are loose and need to be fixed or replaced | 4 | Edit |
| Damaged Bricks | Several bricks are weathered and damaged; the affected masonry should be cut out and replaced | 5 | Edit |
| Damaged Stone | A number of stones are weathered and damaged. The affected masonry should be cut out and replaced to prevent further deterioration | 6 | Edit |
| Parapet Wall Damaged | The parapet wall is damaged where visible and needs to be repaired | 7 | Edit |
| Ongoing Movement Front | Cracking is present to the front elevation. Further investigation by a Chartered Structural Engineer is recommended | 8 | Edit |
| Ongoing Movement Rear | Cracking is present to the rear elevation. Further investigation by a Chartered Structural Engineer is recommended | 9 | Edit |
| Ongoing Movement Left | Cracking is present to the left elevation. Further investigation by a Chartered Structural Engineer is recommended | 10 | Edit |
| Ongoing Movement Right | Cracking is present to the right elevation. Further investigation by a Chartered Structural Engineer is recommended | 11 | Edit |
| Ongoing Movement Bay Window | Cracking is present to the bay window. Further investigation by a Chartered Structural Engineer is recommended | 12 | Edit |
| Ongoing Movement Main Walls | Cracking is present to the main walls. Further investigation by a Chartered Structural Engineer is recommended | 13 | Edit |
| Ongoing Movement Extension Walls | Cracking is present to the extension walls. Further investigation by a Chartered Structural Engineer is recommended | 14 | Edit |
| Ongoing Distortion Front | Distortion is evident to the front elevation. Further investigation by a Chartered Structural Engineer is recommended | 15 | Edit |
| Ongoing Distortion Rear | Distortion is evident to the rear elevation. Further investigation by a Chartered Structural Engineer is recommended | 16 | Edit |
| Ongoing Distortion Left | Distortion is evident to the left elevation. Further investigation by a Chartered Structural Engineer is recommended | 17 | Edit |
| Ongoing Distortion Right | Distortion is evident to the right elevation. Further investigation by a Chartered Structural Engineer is recommended | 18 | Edit |
| Ongoing Distortion Bay Window | Distortion is evident to the bay window. Further investigation by a Chartered Structural Engineer is recommended | 19 | Edit |
| Ongoing Distortion Main Walls | Distortion is evident to the main walls. Further investigation by a Chartered Structural Engineer is recommended | 20 | Edit |
| Ongoing Distortion Extension Walls | Distortion is evident to the extension walls. Further investigation by a Chartered Structural Engineer is recommended | 21 | Edit |
| Thin Walls Possible Damp | The slender walls to the property are uninsulated and are therefore susceptible to condensation, penetrating dampness, and significant heat loss. It is recommended that the walls be upgraded to improve thermal performance | 22 | Edit |
| Low DPC No Damp | The damp proof course is positioned too close to the external ground level. Although no dampness was detected at the time of inspection, the ground level should be lowered slightly to reduce the risk of future damp penetration | 23 | Edit |
| Finishes Bridge DPC Render to Ground | The render has been carried down too close to ground level, which can lead to dampness within the walls. It should be cut back and properly finished with a bell-mouth drip to prevent moisture ingress | 24 | Edit |
| Render Hollow | The render sounds hollow when tapped, showing it’s coming away from the wall. It should be repaired to stop damp getting in | 25 | Edit |
| Render Poor | The render is in poor condition and requires repair to reduce the risk of dampness and further deterioration | 26 | Edit |
| Render Coming Away | The render is coming away in places and requires repair to reduce the risk of dampness and further deterioration | 27 | Edit |
| Render Cracked | The render is cracked in places and requires repair to reduce the risk of dampness and further deterioration | 28 | Edit |
| Painted Finishes Poor | The painted finishes are deteriorating, which may trap moisture and lead to further damage. Repairs and redecoration are required to reduce the risk of dampness and ongoing deterioration | 29 | Edit |
| Localised Repointing | The mortar pointing is weathered, and localised repointing is required to prevent further deterioration | 30 | Edit |
| Bricks Weathered | Some bricks are weathered and damaged, and localised repairs are required to prevent further deterioration | 31 | Edit |
| Stones Weathered | Some stones are weathered and damaged, and localised repairs are required to prevent further deterioration | 32 | Edit |
| Bricks Missing | Some bricks are missing, and localised repair and making good are required to restore the masonry | 33 | Edit |
| Stones Missing | Some stones are missing, and localised repair and making good are required to restore the masonry and prevent further deterioration | 34 | Edit |
| Tile Hanging | Some tiles are broken and require repair or replacement to maintain weather resistance | 35 | Edit |
| Finishes Claddings | Some sections of cladding are damaged and require repair or replacement to maintain weather protection and appearance | 36 | Edit |
| Ivy Growth | Ivy growth is present on the walls, which can cause damage to the masonry. It is recommended that the ivy be removed, and localised repairs may be necessary to the exposed wall surfaces once cleared | 37 | Edit |
| Sills Poor Projection | Some window sills do not project sufficiently beyond the wall face, increasing the risk of dampness. The sills should be improved or replaced to provide adequate overhang and weather protection | 38 | Edit |
| Sills Poor Drip | Some window sills do not have a throating groove on the underside, increasing the risk of dampness to the wall below. The sills should be improved or replaced to incorporate an adequate throating detail | 39 | Edit |
| Sills Tiles Cracked | Some windowsill tiles are cracked and require replacement to reduce the risk of dampness and further deterioration | 40 | Edit |
| Parapet Coping Stones Loose | The coping stones to the parapet walls are loose and should be repaired or replaced to ensure stability and prevent water ingress | 41 | Edit |
| Parapet Coping Stones Weathered | The coping stones to the parapet walls are weathered and should be repaired or replaced to maintain weather protection and prevent further deterioration | 42 | Edit |
| Parapet Coping Stones Missing | The coping stones to the parapet walls are missing and should be reinstated or replaced to provide adequate weather protection and prevent water ingress | 43 | Edit |
| Parapet Coping Stones Damaged | Damaged coping stones were noted to the parapet walls; repair or replacement is required to restore weatherproofing | 44 | Edit |
| Cracking Old Movement | Some cracking is present to the walls. The movement appears longstanding, with no evidence to suggest further movement is occurring. However, repairs are required to reduce the risk of damp penetration and further deterioration | 45 | Edit |
| Distortion Old Movement | Some distortion is present to the walls. The movement appears longstanding, with no evidence to suggest that further movement is occurring | 46 | Edit |