Automated Building Reporting
| Label | Report Text | Sort Order | Actions |
|---|---|---|---|
| No Solar Protection | The roof covering is not protected from the suns harmful rays which could lead to premature deterioration and failure. Improvements are required | 0 | Edit |
| Flat Roof Poor Replacement Needed | The flat roof covering is in poor condition and should now be replaced. There may be associated damage to the roof deck and supports and you should ensure these are checked and repair or replaced as necessary | 1 | Edit |
| Flat Roof End of Life Repair or Replace | The flat roof covering has reached the end of its performance and needs comprehensive overhaul or replacement | 2 | Edit |
| Flashings Poor | Flashings to the flat roof are poor and should be repaired or replaced | 3 | Edit |
| Lead No Expansion Provision | The lead roof does not have sufficient provision for thermal expansion. This may cause the lead to wrinkle or split and improvement is required | 4 | Edit |
| Ponding | I noted standing water has been on the roof caused by poor design which may reduce the life expectancy of the covering. You should seek the advice of a competent roofing contractor as to the appropriate course of action | 5 | Edit |
| Felt Upstands Defective | The felt upstands serving the roof are defective and should be repaired or replaced | 6 | Edit |
| Misted Rooflight | The glazing in the rooflight has misted over due to failure of the seals which cannot be repaired and the glass should be replaced | 7 | Edit |
| Leadwork Lifting | The leadwork is lifting to the roof. It needs to be refixed in position to reduce the risk of leakage | 8 | Edit |
| No Solar Protection (Multiple) | The roof coverings are not protected from the suns harmful rays which could lead to premature deterioration and failure. Improvements are required | 9 | Edit |
| Flat Roofs Poor Replacement Needed (Multiple) | The flat roof covering is in poor condition and should now be replaced. There may be associated damage to the roof deck and supports and you should ensure these are checked and repair or replaced as necessary | 10 | Edit |
| Flat Roofs End of Life Repair or Replace (Multiple) | The flat roof coverings have reached the end of their performance life and need comprehensive overhaul or replacement | 11 | Edit |
| Flashings Poor (Multiple) | Flashings to the flat roofs are poor and should be repaired or replaced | 12 | Edit |
| Lead No Expansion Provision (Multiple) | The lead roof does not have sufficient provision for thermal expansion. This may cause the lead to wrinkle or split and improvement is required | 13 | Edit |
| Ponding (Multiple) | I noted standing water has been on the roofs caused by poor design which may reduce the life expectancy of the covering. You should seek the advice of a competent roofing contractor as to the appropriate course of action | 14 | Edit |
| Felt Upstands Defective (Multiple) | The felt upstands serving the roofs are defective and should be repaired or replaced | 15 | Edit |
| Misted Rooflights (Multiple) | The glazing in the rooflights has misted over due to failure of the seals which cannot be repaired and the glass should be replaced | 16 | Edit |
| Leadwork Lifting (Multiple) | The leadwork is lifting to the roofs. It needs to be refixed in position to reduce the risk of leakage | 17 | Edit |
| Ventilation Insufficient | Ventilation to the roof is insufficient and should be improved | 18 | Edit |
| Ventilation Insufficient (Multiple) | Ventilation to the roofs is insufficient and should be improved | 19 | Edit |