Automated Building Reporting
| Label | Report Text | Sort Order | Actions |
|---|---|---|---|
| Outbuilding - Asbestos Cement Poor Condition | The asbestos cement outbuilding is old and is in a poor state of repair and I recommend it is removed. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken | 0 | Edit |
| Outbuilding - Prefabricated - Remove | The prefabricated outbuilding is old and is in a poor state of repair and I recommend it is removed | 1 | Edit |
| Outbuilding - Poor - Remove | The outbuilding is old and is in a poor state of repair and I recommend it is removed | 2 | Edit |
| Outbuilding - Movement | There is evidence of structural movement to the outbuilding and further investigation by a Structural Engineer should be undertaken | 3 | Edit |
| Outbuilding - Unsafe Glazing | Glazing to the outbuilding is broken and should be replaced | 4 | Edit |
| Outbuilding - Roof Poor - Repair | The outbuilding roof is in poor condition and should be repaired | 5 | Edit |
| Outbuilding - Roof - Leaking Repair | The outbuilding roof appears to be leaking and should be repaired | 6 | Edit |
| Outbuilding Roof - End of Life - Replace | The outbuilding roof is at the end of its life expectancy and should be replaced | 7 | Edit |
| Outbuilding - Beetle | Evidence of wood boring beetles (woodworm) was noted to the outbuilding. You should check whether the timbers have been treated under a guarantee. If there is no evidence of this you should have all affected timbers treated by a member of the Property Care Association or similar | 8 | Edit |
| Outbuilding - No Solar Protection | The outbuilding roof covering is not protected from the suns harmful rays which could lead to premature deterioration and failure. Improvements are required | 9 | Edit |
| Outbuilding - Rotten Joinery | Rotten joinery was noted to the outbuilding and repairs are required | 10 | Edit |
| Outbuilding - Defective Door | The door to the garage is defective and repairs are required | 11 | Edit |
| Outbuilding - Cracking To Floor | Cracking was noted to the outbuilding floor and repairs are required | 12 | Edit |
| Outbuilding - Moss/Lichen To Roof | Vegetation is growing on the surface of the roof reducing water run off which in turn will affect performance of the coverings. It should be carefully removed where build up is occurring | 13 | Edit |
| Outbuilding - Rainwater Leaking No Damp | Some gutters to the outbuilding are leaking and repairs are required to prevent flooding and dampness | 14 | Edit |
| Garage - Rainwater Missing No Damp | Some outbuilding gutters are missing and repairs are required to prevent flooding and dampness | 15 | Edit |