Automated Building Reporting

Admin

Report #56

Back to Past Reports
Report Details
Date: -
Client: Joe Bloggs
Address: 3 Llys Caradog, LL17 0BF
Reference: -
Technical Officer: -
Created: 28/10/2025 07:55:02
Report Entries
Weather During Visit
Button: Foggy
Text: It was foggy when I inspected the property
Energy Matters
Button: EPC Consistent
Text: The property attributes stated within the EPC are consistent with the findings of my inspection
Button: Roadside Parking
Text: Roadside parking is available
External Limitations
Button: Roof Lining Roof Height
Text: I am unable to confirm if the roof lining extends into the rainwater fittings at eaves level as my inspection was restricted by the height and configuration of the roof
Chimney Construction
Button: Flashings Mortar
Text: The flashings around the stack are mortar
Chimney Notes
Button: Mortar Fillets
Text: The mortar fillets to the stack will be prone to deteriorating and will need replacing periodically
Roofs Construction
Button: Dormer Roof - Slate
Text: The dormer roof is covered in slates
Roofs Notes
Button: Extension Roof Possible Asbestos
Text: The extension roof is covered with artificial slates that may contain asbestos. There is a safety risk. Before commencing any work on asbestos containing materials a risk assessment should be undertaken
Flat Roofs Construction
Button: Lead
Text: The flat roof has a lead covering
Rainwater Goods Construction
Button: Gutters Concrete
Text: The rainwater gutters are concrete
Rainwater Goods Defects
Button: Leaking
Text: I noted some stained and possibly leaking sections and resealing is required
Flat Roofs Defects
Button: Flat Roof End of Life Repair or Replace
Text: The flat roof covering has reached the end of its performance and needs comprehensive overhaul or replacement
Roofs Defects
Button: Hip Tiles Loose
Text: Some of the hip tiles are loose and should be refixed or replaced
External Walls Construction
Button: Timber Frame Brick
Text: The walls are of brick faced timber frame construction
External Walls DPC
Button: Engineering Brick DPC
Text: There is a blue brick (engineering brick) damp proof course
External Walls Notes
Button: Replacement DPC to Stone Walls
Text: In solid stone walls such as this replacement damp proof courses are unlikely to be fully effective and degree of dampness will need to be accepted
External Walls Defects
Button: Ongoing Movement Rear
Text: There is cracking to the rear elevation. This needs to be investigated further by a Chartered Structural Engineer
Estimated Repair Cost
Button: £0-£500