Automated Building Reporting

Admin

Report #225

Back to Past Reports
Report Details
Date: -
Client: -
Address: -
Reference: -
Technical Officer: -
Created: 12/02/2026 10:59:25
Report Entries
Internal Limitations
Button: No Restrictions
Text: There are no unusual restrictions to my inspection of the interior of the building
Button: Hatch Main Roof None
Text: There is no access hatch to the main roof space. No inspection was possible
Button: Hatch Extension None
Text: There is no access hatch to the extension roof space. No inspection was possible
Button: Hatch Flat None
Text: There is no access to the roof space from within the subject flat and therefore no inspection was possible
Button: Hatch Sealed
Text: The access hatch is sealed up and this prevented access to the roof space
Button: Hatch Dangerous Location
Text: The access hatch to the roof space is situated in a dangerous location and this prevent access to the roof space
Button: Hatch Obstructed
Text: The access hatch to the roof space is obstructed by stored items and this prevent access to the roof space
Button: Inspection from Hatch
Text: My inspection of the roof space was limited as the insulation has been laid over the joists making movement around the roof space unsafe
Button: Insulation Ostructing
Text: My inspection of the roof space was restricted by the presence of insulation
Button: Loft Boards Obstructing
Text: My inspection of the roof space was restricted by the loft boards
Button: Rafters Hidden - Felt
Text: A lining of felt has been fitted under the rafters which restricted my inspection of the roof structure
Button: Rafters Hidden - Plastic Sheeting
Text: A lining of plastic sheeting has been fitted under the rafters which restricted my inspection of the roof structure
Button: Rafters Hidden - Timber Boarding
Text: Timber boarding has been fitted under the rafters which restricted my inspection of the roof structure
Button: Roof Space - Asbestos
Text: There is suspected asbestos containing material in the roof space and for safety reasons I was unable to complete my inspection
Button: Ceilings Hidden - Timber Cladding
Text: The ceilings were partly hidden by timber cladding
Button: Ceilings Hidden - Plastic Cladding
Text: The ceilings were partly hidden by plastic cladding
Button: Ceilings Hidden - Polystyrene Tiles
Text: The ceilings were partly hidden by polystyrene tiles
Button: Ceilings Hidden - Textured Paper
Text: The ceilings were partly hidden by heavily textured paper
Button: Walls Hidden - Timber Cladding
Text: The walls were partly hidden by timber cladding
Button: Walls Hidden - Plastic Cladding
Text: The walls were partly hidden by plastic cladding
Button: Walls Hidden - Polystyrene Tiles
Text: The walls were partly hidden by polystyrene tiles
Button: Walls Hidden - Textured Paper
Text: The walls were partly hidden by heavily textured paper
Button: Walls Hidden - Ceramic Tiles
Text: The walls were partly hidden by ceramic tiles
Button: Walls Hidden - Shelving
Text: The walls were partly hidden by shelving
Button: Walls Hidden - Hanging Pictures
Text: The walls were partly hidden by hanging pictures
Button: Floors Hidden - Coverings
Text: The carpets and other floor coverings restricted my inspection of the floor structures
Button: Floors Hidden - No Void Access
Text: There was no available access to the void spaces beneath the floors
Button: Damp Restricted - Ceramic Tiling
Text: My inspection for damp was restricted by ceramic tiling
Button: Damp Restricted - Wall Claddings
Text: My inspection for damp was restricted by wall claddings
Button: Damp Restricted - Floor Coverings
Text: My inspection for damp was restricted by floor coverings
Button: Damp Restricted - Fitted Cupboards
Text: My inspection for damp was restricted by fitted cupboards
Button: Restricted - Stored Items
Text: My inspection was generally limited owing to the stored items in the property
Button: Stored Items - Kitchen
Text: The stored goods within the kitchen cupboards prevented a full inspection
Button: Stored Items - Bathroom
Text: The stored goods within the bathroom cupboards prevented a full inspection
Button: Stored Items - Utility Room
Text: The stored goods within the utility room cupboards prevented a full inspection
Button: Stair Carpeting
Text: The stair carpeting limited my assessment of the staircase
Button: Locked Doors - No Keys
Text: Some doors were locked with no keys available and could not be opened
Button: Restricted - Extended
Text: The property has been extended. This means that some of the original parts of the building are now hidden and could not be inspected
Button: Restricted - Altered
Text: The property has been altered. This means that some of the original parts of the building are now hidden and could not be inspected
Button: Restricted - Converted
Text: The property has been converted. This means that some of the original parts of the building are now hidden and could not be inspected
Button: Hidden Defects
Text: There may be hidden defects in the areas I could not inspect. The comments included in this report are based on what was visible to me at the time of inspection
Roof Space Description
Button: No Access
Text: The roof space is not accessible and could not be inspected
Button: Trussed
Text: The roof structure is formed with factory-made timber trusses
Button: Rafter & Purlin
Text: The roof structure is formed with timber rafters and purlins
Button: TRADA
Text: The roof structure is formed with timber rafters, purlins, and bolted timber roof trusses
Button: No Felt
Text: The roof is unlined, with the underside of the roof covering exposed
Button: Felt
Text: The roof is lined with felt underlay
Button: Breathable
Text: The roof is lined with a breathable underlay
Button: Cosy Felt
Text: The roof has a cosy felt insulation lining
Button: Perforated Plastic Sheet
Text: Perforated plastic sheeting has been used to line the roof
Button: Timber Boarding
Text: The roof is lined with timber boarding
Button: Insulated
Text: The loft has insulation laid between and over the ceiling joists
Button: No Insulation
Text: No insulation is present to the main roof
Button: Bonded Insulation
Text: Fibreglass insulation is bonded to the underside of the roof lining
Button: Loft Conversion
Text: The loft has been converted into a usable room
Roof Space Advice
Button: Shakes
Text: Some of the roof timbers show horizontal cracks, which are common in timber and not usually a cause for concern
Button: Salt Deposits
Text: Some white crystalline formation was observed on the roof timbers. This is a common occurrence in buildings of this age and causes no deterioration to the timber. No action is needed
Button: Historic Roof Spread
Text: Roof spread has resulted in visible misalignment of the soffit boarding. The movement appears historic and is typical of similar properties locally. There is no indication of progressive movement, and no remedial work is currently required
Button: Torching
Text: Some deterioration was noted to the mortar torching beneath the roof covering. This is not currently of concern, and remedial work is not warranted
Button: Re-Covered
Text: The existing roof has been re-covered with tiles, adding additional weight compared with the original covering. Structural upgrades appear to have been undertaken to support this, with no evidence of defect noted. Such work may have required Local Authority consent
Button: Storage
Text: The roof structure is not designed to support significant storage loads; storage should be limited to light household items only
Button: Bats
Text: Signs of bat activity were observed in the roof space. Bats are legally protected and typically do not cause damage to the structure. While their presence usually poses no problem, droppings may produce odours within the roof area
Ceilings Description
Button: Plasterboard
Text: Plasterboard has been used to form the ceilings
Button: Lath & Plaster
Text: Lath and plaster has been used to form the ceilings
Button: Fibreboard
Text: Fibreboard has been used to form the ceilings
Button: Suspended Concrete
Text: Suspended concrete has been used to form the ceilings
Button: Asbestos Board
Text: Asbestos board has been used to form the ceilings
Button: Painted
Text: The ceilings are painted
Button: Papered
Text: The ceilings are papered
Button: Textured
Text: A textured finish has been applied to the ceilings
Button: uPVC Clad
Text: Ceiling surfaces are finished with uPVC cladding
Button: Timber Clad
Text: Ceiling surfaces are finished with timber cladding
Button: Polystyrene
Text: Ceiling surfaces are finished with polystyrene
Ceilings Advice
Button: Minor Cracks
Text: Minor ceiling cracking was noted; this is common and not structurally significant. Repairs can be carried out at the next redecoration
Button: Lath Minor Cracks
Text: The lath and plaster ceilings are in fair condition with minor cracks noted. They are vulnerable to vibration and may fail suddenly, so regular maintenance should be expected
Button: Artex No Damage
Text: The textured finishes could contain asbestos. These materials are safe if left undisturbed; however, a qualified specialist should carry out a risk assessment before undertaking any work that may disturb them
Button: Fibreboard
Text: Fibreboard ceilings offer poor fire and acoustic performance relative to plasterboard; replacement is recommended
Button: Concealed - Heavy Paper
Text: Heavy paper finishes to some ceilings may hide defects; repairs could be needed if the coverings are stripped
Button: Concealed - Timber Board
Text: Timber board ceiling finishes may hide defects; repairs or improvements could be needed if the boards are removed
Button: Concealed - uPVC
Text: uPVC ceiling finishes may conceal defects; repairs or improvements could be necessary if the coverings are removed
Internal Walls Description
Button: Mainly Solid
Text: Internal walls are predominantly constructed of solid masonry
Button: Mainly Stud Partitions
Text: Internal walls are predominantly constructed of stud partitions
Button: Mainly Hollow Core
Text: Internal walls are predominantly constructed of lightweight hollow core partitions
Button: Timber Framed Partition
Text: Internal walls are predominantly constructed of timber-framed partitions
Button: Painted
Text: The internal walls have a painted finish
Button: Papered
Text: The internal walls have a papered finish
Button: Tiled
Text: Internal wall surfaces are finished with tiles
Button: Timber Clad
Text: Internal wall surfaces are finished with timber cladding
Button: Textured
Text: Internal wall surfaces have a textured finish
Button: Plastic Clad
Text: Internal wall surfaces are finished with plastic cladding
Internal Walls Advice
Button: Minor Cracking
Text: Minor wall cracks were observed; these are typical and not structurally significant. They can be repaired during the next redecoration
Button: Distortion
Text: Minor distortion, mainly around openings, was observed. This is typical and not structurally significant, though doors may occasionally require adjustment
Button: Walls Removed - Building Regulations
Text: Internal walls have been removed, and Building Regulation approval should have been obtained for this alteration
Button: Old Plaster
Text: The old plaster is prone to damage from vibration or disturbance and may be loose in places. Periodic patch repairs will be required
Button: Woodchip Paper
Text: Heavy paper wall finishes may hide defects; repairs or improvements could be needed if the coverings are stripped
Button: Timber Board
Text: Timber board wall finishes may hide defects; repairs or improvements could be needed if the boards are removed
Button: uPVC Wall Finishes
Text: uPVC wall finishes may hide defects; repairs or improvements could be needed if the coverings are removed
Floors Description
Button: Suspended Timber
Text: The floors are of suspended timber construction
Button: Solid
Text: The floors are of solid construction
Button: Suspended Concrete
Text: The floors are of suspended concrete construction
Floors Advice
Button: Old & Springy
Text: Timbers within older floors are likely to be undersized by modern standards and some minor springing has occurred. This is common and no improvements are considered necessary
Fireplaces Description
Button: Open Fire
Text: An open fire is present within the property
Button: Gas Fire
Text: A gas fire is installed within the property
Button: Solid Fuel Stove
Text: A solid fuel stove is installed within the property
Button: Disused Open Fire
Text: The open fire is no longer in use and functions solely as a decorative feature
Button: Blocked Up
Text: The fireplace opening has been sealed
Button: Fireplace Removed
Text: The original fireplace has been removed
Button: Covered Over
Text: The fireplace has been covered over
Fireplaces Advice
Button: Support Seen
Text: Part of the chimney breast has been removed and the remaining masonry supported. Confirmation should be obtained that the work complies with Building Regulations
Button: Stove
Text: The stove should be certified under Building Regulations or installed by a HETAS-registered contractor (or equivalent)
Button: Redundant Asbestos Flue
Text: The redundant flue may contain asbestos. A qualified specialist must complete a risk assessment before any work is undertaken
Button: Disused Fireplace
Text: If the disused fireplace is to be reinstated, repairs and flue lining may be required, potentially at significant cost. Specialist advice should be obtained before proceeding
Button: Check Flues
Text: Flues should be checked and swept prior to use and this should be done by a reputable chimney sweep
Fitted Units Description
Button: Fitted Units - Kitchen
Text: The kitchen is fitted with built-in units
Button: Fitted Units - Utility Room
Text: The utility room is fitted with built-in units
Button: Fitted Units - Master Bedroom
Text: The master bedroom is fitted with built-in units
Button: Fitted Units - Bedrooms
Text: The bedrooms are fitted with built-in units
Fitted Units Advice
Button: Minimal Fittings
Text: Storage and worktop provision is limited for a property of this size; additional fittings should be considered
Button: Basic Quality - Kitchen
Text: Kitchen fittings are of basic quality with a short lifespan and will need regular upkeep
Button: Basic Quality - Utility Room
Text: The utility room fittings are of basic quality, will have a limited life expectancy and require regular maintenance
Button: Basic Quality - Master Bedroom
Text: The master bedroom fittings are of basic quality, will have a limited life expectancy and require regular maintenance
Button: Basic Quality - Bedrooms
Text: The bedroom fittings are of basic quality, will have a limited life expectancy and require regular maintenance
Internal Joinery Description
Button: Internal Joinery
Text: Internal joinery comprises doors, door surrounds, and skirting boards
Button: Internal Joinery & Staircase
Text: Internal joinery comprises doors, door surrounds, skirting boards, and the staircase
Internal Joinery Advice
Button: Three Storey No Fire Door
Text: The property exceeds two storeys and does not comply with current fire safety standards. Although not applied retrospectively, this poses a safety risk; advice should be obtained from the local Fire Prevention Officer
Button: Lead Paint
Text: Given the property’s age, old paint finishes may contain lead. Appropriate precautions should be taken if disturbed
Sanitary Fittings Description
Button: Modern
Text: Modern sanitary fittings are installed
Button: Dated
Text: Dated sanitary fittings are installed
Button: Original
Text: Original sanitary fittings are installed
Sanitary Fittings Advice
Button: Seals
Text: Seals around the sanitary fittings, in particular those around bath and shower cubicles are very prone to leakage. It is important that the seals around the fittings are not allowed to deteriorate and seals should be inspected regularly
Button: Macerator WC
Text: A macerator is fitted to the toilet. These units can be loud when in use and are prone to breakdown and blockage. In addition, they cannot be used if the electricity supply is off
Roof Space Advice
Button: Old Loft Conversion
Text: Insulation levels in older conversions are often below modern standards, leading to substantial heat loss, increased heating expenditure, and potential condensation and mould issues in winter months. Overheating can also occur during warmer periods
Alarms Description
Button: Smoke - Mains
Text: The property has mains powered smoke alarms
Button: Smoke - Battery
Text: The property has battery powered smoke alarms
Button: Carbon Monoxide - Mains
Text: The property has mains powered carbon monoxide alarms
Button: Carbon Monoxide - Battery
Text: The property has battery powered carbon monoxide alarms
Button: Fire - Mains
Text: The property has mains powered fire alarms
Button: Fire - Battery
Text: The property has battery powered fire alarms
Button: Security - Mains
Text: The property has mains powered security alarms
Button: Security - Battery
Text: The property has battery powered security alarms
Heating Description
Button: Gas Combi
Text: Central heating is provided by a gas fired combination boiler
Button: Gas Back Boiler
Text: Central heating is provided by a gas fired back boiler
Button: Radiators
Text: Heating to the rooms is provided by radiators
Button: Under-Floor Circuits
Text: Heating to the rooms is provided by under-floor circuits
Button: Warm Air Ducting
Text: Heating to the rooms is provided by warm air ducting
Button: Expansion Tank - Loft
Text: The expansion tank serving the boiler is located in the roof void
Button: Expansion Tank - Airing Cupboard
Text: The expansion tank serving the boiler is located in the airing cupboard
Button: Tank - Plastic
Text: The tank is made of plastic
Button: Tank - Fibreglass
Text: The tank is made of fibreglass
Button: Tank - Galvanised Steel
Text: The tank is made of galvanised steel
Button: Tank - Asbestos Cement
Text: The tank is made of asbestos cement
Button: Tank - Copper
Text: The tank is made of copper
Button: Ground Source
Text: The property is heated by a ground source heat pump
Button: Air Source
Text: The property is heated by an air source heat pump
Heating (Secondary) Description
Button: Gas Fire
Text: There is a gas fire in the property
Button: Electric Fire
Text: There is an electric fire in the property
Heating Description
Button: Oil Back Boiler
Text: Central heating is provided by an oil fired back boiler
Button: Oil Boiler
Text: Central heating is provided by an oil fired boiler
Heating (Secondary) Description
Button: Storage Heaters
Text: The property is heated by electric storage heaters
Heating Description
Button: Electric Boiler
Text: Central heating is provided by an electric boiler
Heating Advice
Button: Keep Boiler Area Clear
Text: The area surrounding the boiler should be kept clear to help ventilation and prevent damage
Button: Pipes Concrete Floors
Text: Central heating pipes have been installed in the concrete floors. Copper pipes should be protected from cement otherwise they can prematurely fail. I am unable to confirm whether sufficient protection has been installed or to inspect the condition of the pipework
Button: Warm Air Asbestos
Text: Asbestos based materials are commonly utilised in warm air heating systems. If disturbed, the material could release harmful fibres into the property. Before commencing any work on suspected asbestos containing materials, a risk assessment should be carried out
Button: Microbore Pipes
Text: The central heating installation contains some micro bore pipes. They have a tendency to be more prone to blockages from scale build up as well as suffering from physical damage
Drainage Description
Button: Mains Drainage
Text: I believe the property is connected to the public sewer
Button: Mains Drainage - Shared
Text: I believe the property is connected by a shared drainage system to the public sewer
Button: Septic Tank
Text: I believe the property is connected to a septic tank
Button: Septic Tank - Shared
Text: I believe the property is connected by a shared drainage system to a septic tank
Button: Waste Pipes - Plastic
Text: The above ground waste pipes are plastic
Button: Waste Pipes - Cast Iron
Text: The above ground waste pipes are cast iron
Button: Waste Pipes - Asbestos Cement
Text: The above ground waste pipes are asbestos cement
Button: Waste Pipes - Lead
Text: The above ground waste pipes are lead
Drainage Advice
Button: Minimal Falls Drains
Text: The underground drainage pipes have minimal falls. This could result in more frequent blockages and whilst not cost effective to improve, you should budget for more regular maintenance
Button: Asbestos
Text: Asbestos above ground drainage pipes are not normally considered to be a significant health risk, providing that the material is in sound condition and is not disturbed or damaged. Before commencing any work on asbestos containing materials, a risk assessment should be carried out
Button: No Access
Text: No access points to the underground drainage could be located within the curtilage of the site. Clearance of any blockage will be difficult and could be costly
Button: Water Company
Text: The responsibility for many shared underground drainage systems was transferred to local water companies. You should make appropriate enquiries
Button: Septic Tank - Regular Maintenance
Text: Septic tanks require regular maintenance and emptying
Button: Cesspits - Regular Maintenance
Text: Cesspits require regular maintenance and emptying
Button: Drainage Below Extension
Text: The drainage run to the property appears to pass under the extension. No obvious sign of any issues with the drainage run were noted but access should any blockages occur may be difficult
Button: Drainage Below Conservatory
Text: The drainage run to the property appears to pass under the conservatory. No obvious sign of any issues with the drainage run were noted but access should any blockages occur may be difficult
Garages Description
Button: No Garage
Text: The property does not have a garage
Button: Integral Single Garage
Text: The property has an integral single garage
Button: Integral Double Garage
Text: The property has an integral double garage
Button: Attached Double Garage
Text: There is a double garage attached to the property
Button: Attached Triple Garage
Text: There is a triple garage attached to the property
Button: Brick Walls
Text: The garage has brick walls
Button: Rendered Walls
Text: The garage has rendered masonry walls
Button: Precast Concrete Walls
Text: The garage has precast concrete walls
Button: Asbestos Cement Walls
Text: The garage has asbestos cement walls
Button: Flat Roof
Text: There is a flat roof over the garage
Button: Sloping Roof
Text: There is a sloping roof over the garage
Button: Slate Covering
Text: The roof has a slate covering
Button: Tiled Covering
Text: The roof has a tiled covering
Button: Metal Sheet Covering
Text: The roof has a metal sheet covering
Button: Asbestos Covering
Text: The roof has an asbestos covering
Garages Advice
Button: Converted - Not Habitable
Text: The original garage has been converted but it cannot be classed as habitable space. The alterations should have had statutory approval
Button: Converted - Habitable
Text: The original garage has been converted and now forms additional habitable space. The alterations should have had statutory approval
Button: Normal Damp Below DPC
Text: There is some minor damp to the walls and low level. This is a common occurrence in garages where often damp proof courses are positioned above floor level. The damp is not considered serious as this is a non-habitable area
Button: Prefabricated Garages
Text: Garages of this type are considered inferior to traditional masonry constructed garages and are more prone to damp and condensation
Button: Roofs with Limited Life
Text: The flat roof to the garage will have a limited service life when compared to a tiled to slate covered sloping roof. Re-covering will be needed in due course and you should budget for this accordingly
Button: Asbestos OK
Text: There may be an asbestos content to the garage. This is in satisfactory condition and presents no health risks unless it is disturbed
Button: Old Floor Cracks
Text: The concrete floor is cracked. Cracking of this type is common in garage floor slabs and on the basis on my single visual inspection I believe the risk of further movement to be remote
Outbuildings Description
Button: No Outbuildings
Text: The property has no outbuildings
Button: Outside WC
Text: There is an outside WC
Button: Outbuilding
Text: There is an outbuilding
Button: Outbuildings Multiple
Text: There are outbuildings
Outbuildings Advice
Button: Converted - Not Habitable
Text: The former outbuilding has been converted but it cannot be classed as habitable space
Button: Converted - Habitable
Text: The former outbuilding has been converted and now forms additional habitable space. The alterations should have had statutory approval and you should confirm this
Button: Asbestos
Text: There may be an asbestos content to the outbuilding. The asbestos elements should never be cut, drilled or damaged in any way. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken
Button: Flat Roof Limited Life
Text: The flat roof will have a limited service life when compared to a tiled or slate roof
Roof Space Defects
Button: Not Strengthened - Main Roof
Text: The main roof covering has been replaced with heavier tiles, but the roof structure has not been adequately strengthened to support the additional load. Structural improvements are now required. Recovering the roof would have required Building Regulation approval, and you should confirm that this approval was obtained
Button: Not Strengthened - Extension
Text: The extension roof covering has been replaced with heavier tiles, but the roof structure has not been adequately strengthened to support the additional load. Structural improvements are now required. Recovering the roof would have required Building Regulation approval, and you should confirm that this approval was obtained
Button: Defective Structure - Undersized Timbers
Text: The roof structure is defective, with supporting timbers that are undersized. Repair and upgrading are now required to ensure structural stability and safety
Button: Defective Structure - Timbers Cut
Text: The roof structure is defective, as some supporting timbers have been cut through. Repair and upgrading are now required to restore structural integrity and ensure safety
Button: Defective Structure - Poorly Supported
Text: The roof structure is defective, with supporting timbers poorly supported on the walls. Repair and upgrading are now required to ensure adequate structural stability
Button: Building Paper
Text: The main roof has been lined with building paper that now requires replacement. This material may contain asbestos, and if disturbed, harmful fibres could be released into the property. Before carrying out any work on suspected asbestos-containing materials, a risk assessment should be undertaken by a suitably qualified specialist
Button: Spray Foam
Text: The underside of the roof has been sprayed with foam insulation. This increases the risk of concealed timber decay and may adversely affect the future saleability of the property. Further investigation is required to determine the extent of work necessary to remove the material and assess any associated damage
Button: Damaged Felt - Main Roof
Text: The main roof lining is in poor condition and requires repair or replacement. Should replacement be necessary, the roof covering will need to be removed, which is likely to be costly
Button: Damaged Felt - Extension Roof
Text: The extension roof lining is in poor condition and requires repair or replacement. Should replacement be necessary, the roof covering will need to be removed, which is likely to be costly
Button: Woodworm - Main Roof
Text: Wood-boring beetle activity was noted in the main roof space. Confirm whether treatment has been carried out under guarantee; if not, a Property Care Association (PCA) member should undertake treatment
Button: Woodworm - Extension Roof
Text: Wood-boring beetle activity was noted in the extension roof space. Confirm whether treatment has been carried out under guarantee; if not, a Property Care Association (PCA) member should undertake treatment
Button: Timber Decay - Dry Rot
Text: Some of the roof timbers have been affected by dry rot and require repair by a suitably qualified specialist to prevent further deterioration
Button: Timber Decay - Wet Rot
Text: Some of the roof timbers have been affected by wet rot and require repair by a suitably qualified specialist to prevent further deterioration
Button: Party Wall Missing
Text: The party wall is missing and should be constructed up to the underside of the roof covering to provide adequate separation and fire protection between the properties
Button: Party Walls Incomplete
Text: The party wall is incomplete and contains holes and gaps that should be properly sealed to improve fire resistance and security between the properties
Button: Loft Boarding - Loose
Text: Some of the boards laid down for storage and access purposes are loosely supported, and improvements are required to ensure they are safe and adequately secured
Button: Significant Rot - Roof Structure
Text: There is significant timber decay within the roof structure, and repair or replacement of the affected elements is required to ensure structural integrity
Button: Significant Rot - Rafters
Text: There is significant timber decay to the rafters, and repair or replacement of the affected sections is required to maintain structural stability
Button: Significant Rot - Purlins
Text: There is significant timber decay to the purlins, and repair or replacement of the affected sections is required to maintain structural integrity
Button: Significant Rot - Under Valley Gutters
Text: There is significant timber decay to the underside of the valley gutters, and repair or replacement of the affected timbers is required to prevent further deterioration
Button: Significant Rot - Timbers Near Stack
Text: There is significant timber decay to the timbers adjacent to the chimney stack, and repair or replacement of the affected sections is required to maintain structural integrity
Button: Leakage - Flashings
Text: Chimney flashings are leaking; repair is required, and nearby timbers should be inspected for decay
Button: Leakage - Roof Abutments
Text: Roof abutments are leaking; repair is required, and surrounding timbers should be checked for decay
Button: Masonry - Chimney Damp
Text: Dampness was noted to the chimney in the roof space; repairs are needed to prevent ongoing moisture ingress
Button: Masonry - Party Wall Damp
Text: The party wall within the roof space is damp and requires repair to prevent further moisture penetration and deterioration
Button: Masonry - Gable Wall Damp
Text: The gable wall within the roof space is damp and requires repair to prevent further moisture ingress and deterioration
Button: Masonry - Chimney Deteriorating
Text: The chimney within the roof space is deteriorating and requires repair to prevent further decay and potential instability
Button: Masonry - Party Wall Deteriorating
Text: The party wall within the roof space is deteriorating and requires repair to prevent further decay and potential structural issues
Button: Masonry - Gable Wall Deteriorating
Text: The gable wall within the roof space is deteriorating and requires repair to prevent further decay and potential structural damage
Button: Moisture - Lack of Ventilation
Text: Excessive moisture was noted in the roof space, caused by poor ventilation. Improvements are needed to prevent timber decay
Button: Moisture - Inadequate Insulation
Text: Excessive moisture was noted in the roof space, likely caused by insufficient insulation. Improvements are needed to prevent timber decay
Button: Moisture - Extractor Fan In Roof Space
Text: There is excessive moisture within the roof space caused by an extractor fan venting directly into it. This increases the risk of timber decay, and repairs or improvements are required to ensure the fan is properly ducted to the outside
Button: Vermiculite
Text: Loose insulation material, believed to be vermiculite, was noted within the roof space. This material may be contaminated with asbestos fibres and therefore presents a potential health and safety risk. Further investigation and testing should be carried out by a specialist asbestos contractor
Button: Leaking Plumbing
Text: Staining and rot were noted to the timbers, caused by leakage from the central heating installation. Repairs are required to address the leak and replace or treat the affected timbers as necessary
Button: Diagonal Bracing
Text: There is insufficient diagonal bracing between the trusses, and improvements are required to ensure adequate structural stability
Button: Missing End Strapping
Text: The end strapping between the roof structure and the gable wall is missing, and improvements are required to ensure adequate restraint and structural stability
Button: Straps
Text: There is no end strapping between the roof structure and the walls, and improvements are required to provide adequate restraint and structural stability
Button: Underfelt - Patch Repair
Text: The roof underlining is damaged in places, and patch repairs are required to maintain weather protection
Button: Vermin
Text: Evidence of vermin activity was noted in the roof space; pest control treatment is recommended to prevent further infestation
Button: Felt Under Rafters - Ventilation
Text: Felt beneath the rafters is blocking adequate ventilation to the roof space; removal is recommended
Button: Plastic Sheeting Under Rafters - Ventilation
Text: The installation of plastic sheeting beneath the rafters is obstructing roof ventilation; removal is recommended
Button: Timber Boarding - Ventilation
Text: The installation of timber boarding below the rafters is obstructing roof ventilation; removal is recommended
Button: Insulation over Lights
Text: Insulation has been placed over recessed light fittings, increasing the risk of overheating. Improvements are needed to ensure fire safety
Button: Insufficient Insulation
Text: The insulation present is insufficient by modern standards and should be enhanced to improve efficiency
Button: Ventilation
Text: Ventilation within the roof space is inadequate; enhancement is needed to reduce the risk of condensation forming
Ceilings Defects
Button: Ceiling Poor
Text: The ceiling is in poor condition and requires repair or replacement to restore its appearance and integrity
Button: Ceilings Poor (Multiple)
Text: The ceilings are in poor condition and require repair or replacement to restore their appearance and integrity
Button: Ceiling Sagging
Text: The ceiling is sagging and requires repair or replacement to prevent potential collapse and ensure safety
Button: Ceilings Sagging (Multiple)
Text: The ceilings are sagging and require repair or replacement to prevent potential collapse and ensure safety
Button: Ceiling Water Damaged
Text: The ceiling is water damaged and requires repair or replacement to prevent potential collapse and ensure safety
Button: Ceilings (Multiple) Water Damaged
Text: The ceilings are water damaged and requires repair or replacement to prevent potential collapse and ensure safety
Button: Damaged Artex
Text: The textured finishes are defective. These types of finishes may contain asbestos. Before carrying out any work that may disturb asbestos-containing materials, a risk assessment should be undertaken by a suitably qualified specialist
Button: Polystyrene Tiles
Text: Polystyrene ceiling finishes are a fire risk and should be removed. The plaster underneath may require repair once exposed
Button: Damp from Sanitary Leak
Text: Damp staining, likely from leaking sanitary fittings, was observed. Repairs are needed, and nearby timbers should be checked for decay
Button: Damp from Valley Gutter
Text: Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the valley gutter. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary
Button: Damp from Rainwater Fittings
Text: Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the rainwater fittings. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary
Button: Damp from Roof Coverings
Text: Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the roof coverings. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary
Button: Damp from Defective Flashings
Text: Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from defective flashings. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary
Button: Damp from Chimney
Text: Damp staining was noted to the ceiling, which appears to have been caused by rainwater ingress from the chimney. Repairs and improvements are required, and there is a risk of associated decay to adjacent timbers. These should also be inspected and treated or repaired as necessary
Button: Mould to Bathroom Ceiling
Text: Mould growth was noted to the bathroom ceiling, caused by condensation. The affected areas should be cleaned and redecorated as necessary. Heating and ventilation should be improved to help reduce the likelihood of recurrence
Button: Woodworm to Timbers
Text: Wood-boring beetle activity was observed in the exposed beams/timber cladding. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a Property Care Association (PCA) member is recommended
Button: Ceiling Cracked
Text: The ceiling is cracked, and localised repair is required to restore the finish
Button: Ceilings Cracked (Multiple)
Text: The ceilings are cracked, and localised repairs are required to restore the finishes
Button: Ceiling Water Stained
Text: The ceiling is water stained, and localised repair and redecoration are required
Button: Ceilings (Multiple) Water Stained
Text: The ceilings are water stained, and localised repair and redecoration are required
Button: Ceiling Damaged
Text: The ceiling is damaged, and localised repair is required to restore the finish
Button: Ceilings (Multiple) Damaged
Text: The ceilings are damaged, and localised repairs are required to restore the finishes
Button: Coving Poor
Text: The coving is defective in places and requires repair or replacement to restore its appearance
Button: Damp Staining - Roof Leak
Text: The ceiling has been affected by damp resulting from a roof leak. The damaged areas require repair once the source of the leak has been resolved
Button: Damp Staining - Plumbing Leak
Text: The ceiling has been affected by damp resulting from a plumbing leak. The damaged areas require repair once the leak has been rectified
Button: Damp Staining (Multiple) - Roof Leaks
Text: A number of ceilings have been affected by damp resulting from a plumbing leak. The damaged areas require repair once the leak has been rectified
Button: Damp Staining - Plumbing Leaks (Multiple)
Text: A number of ceilings have been affected by damp resulting from a plumbing leak. The damaged areas require repair once the source of the leak has been rectified
Button: Damp Staining - Floor Above
Text: The ceiling has been affected by damp as a result of a leak from the floor above. The damaged areas require repair once the source of the leak has been rectified
Button: Damp Staining Floor Above (Multiple)
Text: The ceilings have been affected by damp as a result of a leak from the floor above. The damaged areas require repair once the source of the leak has been rectified
Button: Minor Mould - Bathroom Ceiling
Text: Mould growth was noted to the bathroom ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould - Ensuite Ceiling
Text: Mould growth was noted to the ensuite ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould - Kitchen
Text: Mould growth was noted to the kitchen ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould - Utility Room
Text: Mould growth was noted to the utility room ceiling, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould Ceilings (Multiple)
Text: Mould growth was noted to some ceilings, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Internal Walls Defects
Button: Rising Damp - DPC Not Effective
Text: High damp meter readings were recorded to the ground floor walls, likely caused by the absence or failure of an effective damp-proof course. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works
Button: Rising Damp - High Ground Level
Text: High damp meter readings were recorded to the ground floor walls, which appear to have been caused by high external ground levels. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works
Button: Rising Damp - Render Bridging
Text: High damp meter readings were recorded to the ground floor walls, which appear to have been caused by external render bridging the damp-proof course. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works
Button: Rising Damp - Salts
Text: High damp meter readings were recorded to the ground floor walls, which appear to have been caused by salt-contaminated plaster. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works
Button: Rising Damp - Failed DPC
Text: High damp meter readings were recorded to the ground floor walls, which appear to have been caused by failure of the damp-proof course. Further investigation by a specialist contractor who is a member of the Property Care Association (PCA) or similar is required to determine the extent of the dampness and the cost of remedial works. There is also a risk of associated decay to adjacent timbers, which should be inspected and treated or repaired as necessary
Button: Penetrating Damp - Weathered Masonry
Text: High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of weathered masonry. Repairs and improvements are required to prevent further moisture ingress
Button: Penetrating Damp - Defective Render
Text: High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of defective render. Repairs and improvements are required to prevent further moisture ingress
Button: Penetrating Damp - Defective Rainwater Fittings
Text: High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of defective rainwater fittings. Repairs and improvements are required to prevent further moisture ingress
Button: Penetrating Damp - Inadequate Window Sills
Text: High damp meter readings were recorded, with evidence suggesting that damp is penetrating through the wall as a result of inadequate window sills. Repairs and improvements are required to prevent further moisture ingress
Button: Condensation - Kitchen
Text: High damp meter readings, along with mould growth, were noted in the kitchen. This is caused by condensation. The affected areas should be cleaned, and the finishes made good. Heating and ventilation should be improved to help reduce the likelihood of recurrence
Button: Condensation - Bathroom
Text: High damp meter readings, along with mould growth, were noted in the bathroom. This is caused by condensation. The affected areas should be cleaned, and the finishes made good. Heating and ventilation should be improved to help reduce the likelihood of recurrence
Button: Woodworm
Text: Wood-boring beetle activity was observed in the wall timbers. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a Property Care Association (PCA) member is recommended
Button: Possible Structural Movement - Ground Floor
Text: Cracking was noted to the ground floor, which may be indicative of structural movement. Further investigation is required by a Chartered Structural Engineer to determine the cause and necessary remedial works
Button: Possible Structural Movement - First Floor
Text: Cracking was noted to the first floor, which may be indicative of structural movement. Further investigation is required by a Chartered Structural Engineer to determine the cause and necessary remedial works
Button: Walls Removed - Poorly Supported - Cracking
Text: Internal alterations have been carried out to remove walls. The support provided may be inadequate, as evidenced by cracking. Further investigation is required by a Chartered Structural Engineer to assess adequacy and recommend any necessary remedial works
Button: Walls Removed - Poorly Supported - Distortion
Text: Internal alterations have been carried out to remove walls. The support provided may be inadequate, as evidenced by distortion. Further investigation is required by a Chartered Structural Engineer to assess adequacy and recommend any necessary remedial works
Button: Plaster - Loose
Text: Sections of plaster are loose and require replastering to restore the finish
Button: Plaster - Cracked
Text: Sections of plaster are cracked and require replastering to restore the finish
Button: Artex
Text: Textured finishes may contain asbestos and can release fibres if disturbed. A qualified specialist should complete a risk assessment before any work is undertaken
Internal Limitations
Button: Walls - Dry Lined
Text: Some walls are dry lined which could be concealing defects such as dampness and cracking
Internal Walls Defects
Button: Minor Mould - Kitchen
Text: Minor mould growth was noted to the kitchen walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould - Bathroom
Text: Minor mould growth was noted to the bathroom walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould - Bedroom
Text: Minor mould growth was noted to the bedroom walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Minor Mould - General
Text: Minor mould growth was noted to the walls, caused by condensation. The affected areas should be cleaned and the finishes made good as necessary. Heating and ventilation should be improved to help prevent recurrence
Button: Localised Damp
Text: Localised damp readings were noted to the ground floor walls; repairs are needed to resolve the issue
Button: Minor Plaster Defects - Cracked
Text: Cracking was noted to sections of plaster; repairs are required
Button: Minor Plaster - Loose
Text: Some plaster is loose and needs to be repaired
Button: Minor Plaster - Water Stained
Text: Sections of plaster are water stained and require repair and redecoration once the source of moisture has been resolved
Button: Minor Plaster - Damaged
Text: Some plaster is damaged and needs to be repaired
Button: Decorations Poor
Text: Internal decorations are in poor condition and require improvement. Some minor plaster repairs may be needed where fittings are removed
Button: Defective Tiling - Bathroom
Text: The tiling in the bathroom is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance
Button: Defective Tiling - Shower Room
Text: The tiling in the shower room is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance
Button: Defective Tiling - Kitchen
Text: The tiling in the kitchen is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance
Button: Defective Tiling - WC
Text: The tiling in the WC is defective and should be repaired or replaced to restore an appropriate finish and maintain water resistance
Floors Defects
Button: Floors Springing
Text: The floors are springing excessively, indicating possible weakness or looseness in the structure. Repair works are required to ensure stability and safety
Button: Floors Sloping
Text: The floors are sloping excessively, indicating possible structural movement or deflection. Repairs are required to restore proper levels and stability
Button: Floors Sagging
Text: The floors are sagging excessively, suggesting possible structural weakness or deflection. Repairs are required to restore stability and alignment
Button: Poor Ventilation
Text: Floor ventilation is inadequate. Improvements are required, and concealed timbers should be inspected by a Property Care Association (PCA) member
Button: Trip Hazard
Text: Uneven flooring was noted in places, presenting a trip hazard that requires attention
Button: Damp Solid Floors - Leak
Text: Damp was observed to the solid floor, likely resulting from a plumbing leak. Repairs are required following correction of the leak
Button: Damp Solid Floors - Lack of DPM
Text: Evidence of damp was noted to the solid flooring, which appears to have been caused by the lack of suitable damp-proofing within the floor construction. Repairs and improvements are required to prevent further moisture ingress
Button: Leak - Risk of Rot
Text: The internal leak presents a risk of hidden floor decay. Further investigation by a Property Care Association (PCA) member is recommended
Button: Damp - Risk of Rot
Text: The dampness found presents a risk of hidden floor decay. Further investigation by a Property Care Association (PCA) member is recommended
Button: Solid Floors - Cracked
Text: The floors are significantly cracked, and repairs or improvements are required to restore an even surface
Button: Damaged Floorboards
Text: Damaged floorboards were noted and require repair or replacement. Further defects may be revealed once coverings are lifted
Button: Creaking Boards
Text: Creaking was noted to some floors. While not structurally significant, repairs could be carried out to minimise noise if desired
Button: Floor Tiles - Poor
Text: Floor tiles were noted to be in poor condition; repair or replacement is required
Button: Laminate Flooring - Poor
Text: The laminate flooring was noted to be in poor condition; repair or replacement is required
Fireplaces Defects
Button: Chimney Breast Removed - Unsupported
Text: The removal of the chimney breast has left unsupported masonry above; structural repairs are needed to provide proper support
Button: Chimney Breasts Removed (Multiple) - Unsupported
Text: Removal of the chimney breasts has left unsupported masonry above; structural repairs are needed to provide proper support
Button: Chimney Breast Removed - Not Seen
Text: The chimney breast has been removed, but the adequacy of support to the remaining masonry could not be confirmed. A detailed inspection is recommended
Button: Chimney Breasts Removed (Multiple) - Not Seen
Text: The chimney breasts have been removed, but the adequacy of support to the remaining masonry could not be confirmed. A detailed inspection is recommended
Button: Gallows
Text: The chimney breast has been removed, and the remaining masonry is supported on gallows brackets within the roof space. This is considered a poor method of support, and an alternative arrangement that complies with current Building Regulations should be installed
Button: Damp - Rain in Flue
Text: High damp meter readings were noted to the chimney breasts, which are likely due to rainwater ingress through the flue. Repairs are required to prevent further moisture penetration and deterioration
Button: Damp - Acidic Deposits
Text: High damp meter readings were noted to the chimney breasts, which are likely due to acidic flue deposits leaching through the masonry. Repairs are required to prevent further moisture penetration and deterioration
Button: Hearth Missing
Text: The hearth is absent, creating a safety hazard. A compliant hearth should be fitted before the fireplace is used
Button: Hearth Poor Projection
Text: The hearth projection is inadequate and poses a safety hazard. A compliant hearth should be provided before the fireplace is used
Button: Hearth Combustible
Text: The existing hearth is combustible and poses a safety hazard. A compliant, non-combustible hearth should be fitted before the fireplace is used
Button: Stove - Too Large
Text: The stove is oversized for the opening and poses a safety hazard. The installation should be checked by a HETAS-registered technician
Button: Stove - Close to Combustible Material
Text: The stove is too close to combustible materials and poses a fire risk. The installation should be checked by a HETAS-registered technician
Button: Stove - Door Seals Worn
Text: Worn stove door seals pose a potential safety hazard. The installation should be checked by a HETAS-registered technician
Button: Stove - Defective Fireback
Text: The stove fireback is defective and poses a safety hazard. The installation should be checked by a HETAS-registered technician
Button: Stove - Poorly Installed Flue
Text: The stove flue installation is defective and poses a safety hazard. It should be checked by a HETAS-registered technician
Button: Stove - Old
Text: The stove appears dated and may not comply with modern safety or efficiency standards. Inspection by a HETAS-registered technician is advised
Button: Stove - Not Cleaned & Serviced
Text: It is unclear when the stove and flue were last serviced. These should be cleaned and serviced annually by a HETAS-registered technician or similar before use
Button: Stove - Fireback Missing
Text: The stove fireback is missing and poses a safety hazard. The installation should be checked by a HETAS-registered technician
Button: Inadequate Ventilation - Open Fire
Text: Ventilation to the room containing the open fire appears inadequate and may pose a safety risk. A HETAS-registered technician should assess the ventilation provision
Button: Inadequate Ventilation - Log Burner
Text: Ventilation to the room containing the log burner appears inadequate and may pose a safety risk. A HETAS-registered technician should assess the ventilation provision
Button: Inadequate Ventilation - Stove
Text: Ventilation to the room containing the stove appears inadequate and may pose a safety risk. A HETAS-registered technician should assess the ventilation provision
Button: Damaged Asbestos Flue
Text: The asbestos cement flue is damaged and should be replaced. A qualified specialist must complete a risk assessment before any work is undertaken
Button: Flue Render
Text: The flue render in the roof space is damaged and needs repair
Button: Chimney Breast Pointing
Text: Pointing to the chimney breast in the roof space is poor and requires repointing
Button: Blocked Fireplaces (Multiple) - Not Vented
Text: The redundant flues lack ventilation; improvements are needed to prevent moisture build-up
Button: Blocked Fireplace - Not Vented
Text: The redundant flue lacks ventilation; improvements are needed to prevent moisture build-up
Fitted Units Defects
Button: Fittings - Dated Replace
Text: The fittings are dated and should be replaced to improve appearance and functionality
Button: Fittings - Poor Condition Replace
Text: The fittings are in poor condition and should be replaced to restore functionality and appearance
Button: Glass Broken - Mirrored Wardrobe
Text: The glass in the mirrored wardrobe is defective and should be replaced to ensure safety and appearance
Button: Mirrored Cupboard - Glass Broken
Text: The glass in the mirrored cupboard is defective and should be replaced to ensure safety and maintain appearance
Button: Water Damaged Unit - Kitchen
Text: The kitchen fittings are water damaged and should be repaired or replaced as necessary
Button: Water Damaged - Utility Room
Text: The fittings in the utility room are water damaged and should be repaired or replaced as necessary
Button: Water Damaged - Bathroom
Text: The fittings in the bathroom are water damaged and should be repaired or replaced as necessary
Button: Fittings - Poorly Supported
Text: Some fittings are poorly supported, and repair work is required to ensure stability and safety
Button: Units - Damaged
Text: Some fitted units are damaged and require repair to restore their condition and functionality
Button: Worktops - Damaged
Text: Some worktops are damaged and require repair or localised replacement to restore their condition and appearance
Button: Worktop - Not Sealed
Text: Inadequate edge sealing to the worktop was noted; repairs are needed to prevent moisture damage to adjoining areas
Internal Joinery Defects
Button: Unsafe Glazing
Text: Some door glazing lacks markings confirming safety glass. To minimise injury risk, the glass should be replaced with toughened or laminated glass
Button: Staircase - Steep
Text: The staircase is excessively steep and poses a safety hazard. Urgent remedial action is recommended
Button: Staircase - Missing Handrail
Text: The staircase lacks a handrail and poses a safety hazard. A compliant handrail should be installed urgently
Button: Staircase - Loose Handrail
Text: The handrail to the staircase is loose and poses a safety hazard. It should be repaired or replaced urgently
Button: Open Riser Stairs
Text: The open staircase poses a safety hazard, particularly to small children. The open risers should be enclosed to improve safety
Button: Gaps in Balustrade - Stairs
Text: The stair guarding contains gaps wide enough to pose a risk to children. Safety improvements are needed
Button: Woodworm - Skirting Boards
Text: Wood-boring beetle activity was observed in the skirting boards. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a PCA member is recommended
Button: Woodworm - Staircase
Text: Wood-boring beetle activity was observed in the staircase timbers. Confirm whether treatment has been carried out under guarantee; if not, a full inspection and treatment by a PCA member is recommended
Button: Timber Decay - Staircase
Text: Rot was noted to the staircase; replacement is required
Button: Timber Decay - Skirting Boards
Text: Rot was noted to the skirting boards; replacement is required
Button: Timber Decay - Window Sills
Text: Rot was noted to the window sills; replacement is required
Button: Timber Decay - Door Surrounds
Text: Rot was noted to the door surrounds; replacement is required
Button: Asbestos
Text: Some internal joinery may contain asbestos. A qualified specialist must carry out a risk assessment before any work is undertaken
Button: Multiple Floors - Self Closers
Text: As the property extends over several floors, doors to the escape route should be fire-resisting. Some self-closers are defective, creating a safety risk; remedial works are needed
Button: Multiple Floors - Smoke Seals
Text: As the property extends over several floors, doors to the escape route should be fire-resisting. Some smoke seals are defective, posing a safety risk; remedial works are required
Button: Skirting Boards - Damaged
Text: Damaged skirting boards were noted; repair or replacement is required
Button: Door Surrounds - Damaged
Text: Damaged door surrounds were noted; repair or replacement is required
Button: Skirting Boards - Poorly Fitted
Text: Poorly fitting skirting boards were noted; repair or replacement is required
Button: Door Surrounds - Poorly Fitting
Text: Poorly fitting door surrounds were noted; repair or replacement is required
Button: Doors - Missing
Text: Missing doors were noted; replacement is required
Button: Doors - Adjust
Text: Several doors need adjustment to operate correctly
Button: Decorations
Text: Some internal joinery items are in need of decoration
Button: Creaking Staircase
Text: The stairs creak when walked on — you may want to have the treads repaired or tightened
Sanitary Fittings Defects
Button: Poor Seals - Toilet
Text: The seals around the toilet are starting to deteriorate and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Poor Seals - Sink
Text: The seals around the sink are starting to deteriorate and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Poor Seals - Bath
Text: The seals around the bath are starting to deteriorate and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Poor Seals - Shower Tray
Text: The seals around the shower tray are starting to deteriorate and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Missing Seals - Toilet
Text: The seals around the shower tray are missing and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Missing Seals - Sink
Text: The seals around the sink are missing and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Missing Seals - Bath
Text: The seals around the bath are missing and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Missing Seals - Shower Tray
Text: The seals around the shower tray are missing and need urgent replacement to reduce the risk of leakage and damage to other elements
Button: Toilet - Damaged
Text: The toilet is damaged. It requires repair or replacement
Button: Sink - Damaged
Text: The sink is damaged. It requires repair or replacement
Button: Bath - Damaged
Text: The bath is damaged. It requires repair or replacement
Button: Shower Tray - Damaged
Text: The shower tray is damaged. It needs repair or replacement
Button: Shower - Screen Damaged
Text: The shower screen is defective and should be replaced
Button: Shower - Screen Not Toughened
Text: The glass to the shower screen has no markings to indicate toughened or laminated safety glass is present. To reduce the risk of injury from accidental breakage the glass should be replaced
Button: Asbestos Bath Panel
Text: An asbestos content is suspected in the damaged bath panel and should be replaced. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken
Button: Asbestos Toilet Cistern
Text: An asbestos content is suspected in the damaged toilet cistern and should be replaced. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken
Button: Sink Seals
Text: The sink is not properly sealed at is edges. This should be improved to prevent water damage to adjacent surfaces
Button: Loose Taps Kitchen
Text: The taps to the kitchen are loose and require repair or replacement
Button: Loose Taps Utility Room
Text: The taps to the utility room are loose and require repair or replacement
Button: Loose Taps Bathroom
Text: The taps to the bathroom are loose and require repair or replacement
Button: Leaking Taps Kitchen
Text: The taps to the kitchen are leaking and require repair or replacement
Button: Leaking Taps Utility Room
Text: The taps to the utility room are leaking and require repair or replacement
Button: Leaking Taps Bathroom
Text: The taps to the bathroom are leaking and require repair or replacement
Estimated Repair Cost
Button: Estimated Cost
Text: I estimate the cost of the above Outbuildings works to be approximately:
Button: £0-£500
Text: £0-£500
Button: £500-£1500
Text: £500-£1500
Button: £1500-£2500
Text: £1500-£2500
Button: £2500-£5000
Text: £2500-£5000
Button: £5000+
Text: £5000+
Alarms Defects
Button: No Smoke Alarms
Text: There are no smoke alarms. This is a safety risk and suitable alarms (preferably mains operated) should be installed at appropriate locations to give early warning
Button: No Carbon Monoxide Alarms
Text: There are no carbon monoxide alarms. This is a safety risk and suitable alarms (preferably mains operated) should be installed at appropriate locations to give early warning
Button: Damaged Smoke Alarms
Text: The smoke alarms are damaged and should be replaced
Button: Damaged Carbon Monoxide Alarms
Text: The carbon monoxide alarms are damaged and should be replaced
Drainage Defects
Button: Inspection Chamber Cover Damaged - Front
Text: The inspection chamber cover to the front elevation is damaged and should be replaced
Button: Inspection Chamber Cover Damaged - Rear
Text: The inspection chamber cover to the rear elevation is damaged and should be replaced
Button: Inspection Chamber Cover Damaged - Left Side
Text: The inspection chamber cover to the left side elevation is damaged and should be replaced
Button: Inspection Chamber Cover Damaged - Right Side
Text: The inspection chamber cover to the right side elevation is damaged and should be replaced
Button: Soil Stack Loose - Repair
Text: The vertical above ground drainage pipe is loose and repair is required
Button: Soil Stack Damaged - Repair
Text: The vertical above ground drainage pipe is damaged and repair is required
Button: Soil Stack Corroded - Repair
Text: The vertical above ground drainage pipe is corroded and repair is required
Button: Soil Stack Leaking - Repair
Text: The vertical above ground drainage pipe is leaking and repair is required
Button: Soil Stack Missing Balloon - Repair
Text: The vertical above ground drainage pipe is missing a capping balloon terminal and repair is required
Button: Soil Stack Venting Close To Opening - Repair
Text: The vertical above ground drainage pipe is venting close to an opening and repair is required
Button: Waste Pipes Loose - Repair
Text: Some waste pipes are loose and repair is required
Button: Waste Pipes Poorly Supported - Repair
Text: Some waste pipes are poorly supported and repair is required
Button: Waste Pipes Cracked - Repair
Text: Some waste pipes are cracked and repair is required
Button: Waste Pipes Leaking - Repair
Text: Some waste pipes are leaking and repair is required
Button: Waste Pipes Corroding - Repair
Text: Some waste pipes are corroding and repair is required
Button: UV Affected
Text: Components have been affected by UV sunlight and will have become brittle. Replacement is required
Button: Blocked Gulley
Text: The gulley has become blocked with debris and should be cleared to prevent localised flooding during periods of high rainfall
Button: Blocked Gulleys (Multiple)
Text: Some of the gulleys have become blocked with debris and they should be cleared to prevent localised flooding during periods of high rainfall
Button: Gulley Grates - Damaged
Text: Gratings to some gullies are damaged and improvements are needed to prevent debris entering the drainage system and causing blockages
Button: Gulley Grates - Missing
Text: Gratings to some gullies are missing and improvements are needed to prevent debris entering the drainage system and causing blockages
Button: Blocked
Text: Where accessible the drains are blocked by debris. A reputable drainage contractor should clear the blockage and test the drains
Button: Inspection Chamber Damaged - Front
Text: The inspection chamber to the front elevation is in need of repair
Button: Inspection Chamber Damaged - Rear
Text: The inspection chamber to the rear elevation is in need of repair
Button: Inspection Chamber Damaged - Left Side
Text: The inspection chamber to the left side elevation is in need of repair
Button: Inspection Chamber Damaged - Right Side
Text: The inspection chamber to the right side elevation is in need of repair
Button: Asbestos Waste Pipes
Text: Sections of the above ground waste pipes appear to be of asbestos containing material and they now need to be replaced. Before commencing any work on asbestos containing materials a risk assessment should be undertaken
Button: Inspection Chamber Missing - Front
Text: The inspection chamber cover to the front is missing and should be replaced
Button: Inspection Chamber Missing - Rear
Text: The inspection chamber cover to the rear is missing and should be replaced
Button: Inspection Chamber Missing - Left Side
Text: The inspection chamber cover to the left side is missing and should be replaced
Button: Inspection Chamber Missing - Right Side
Text: The inspection chamber cover to the right side is missing and should be replaced
Button: Discharging to Rainwater Downpipe - Bathroom
Text: The fittings in the bathroom discharge to a rainwater downpipe. The fittings should be redirected to discharge into the foul drainage system
Button: Discharging to Rainwater Downpipe - Shower Room
Text: The fittings in the shower room discharge to a rainwater downpipe. The fittings should be redirected to discharge into the foul drainage system
Button: Discharging to Rainwater Downpipe - En-Suite
Text: The fittings in the en-suite discharge to a rainwater downpipe. The fittings should be redirected to discharge into the foul drainage system
Button: Discharging to Rainwater Downpipe - Cloakroom
Text: The fittings in the cloakroom discharge to a rainwater downpipe. The fittings should be redirected to discharge into the foul drainage system
Button: Waste Pipes Leaking - Kitchen
Text: The waste pipes in the kitchen are leaking and need urgent attention to prevent damage to other elements
Button: Waste Pipes Leaking - Utility Room
Text: The waste pipes in the utility room are leaking and need urgent attention to prevent damage to other elements
Button: Waste Pipes Leaking - Bathroom
Text: The waste pipes in the bathroom are leaking and need urgent attention to prevent damage to other elements
Button: Waste Pipes Leaking - En-Suite
Text: The waste pipes in the en-suite are leaking and need urgent attention to prevent damage to other elements
Button: Waste Pipes Leaking - WC
Text: The waste pipes in the WC are leaking and need urgent attention to prevent damage to other elements
Button: Pitch Fibre Drains Suspected
Text: Based on my inspection I suspect the below ground drains are of pitch fibre construction. These can be prone to collapse and I recommend that you commission a precautionary CCTV survey of the underground drainage
Button: CCTV Survey Due To Defects
Text: I recommend that you commission a precautionary CCTV survey of the underground drainage because of the defects noted.
Button: Downpipes To Ground - Front
Text: The rainwater downpipe to the front elevation discharges directly onto the ground. This is unsatisfactory and can lead to damp, localised flooding and in some cases structural defects. This arrangement should be improved
Button: Downpipes To Ground - Rear
Text: The rainwater downpipe to the rear elevation discharges directly onto the ground. This is unsatisfactory and can lead to damp, localised flooding and in some cases structural defects. This arrangement should be improved
Button: Downpipes To Ground - Left Side
Text: The rainwater downpipe to the left side elevation discharges directly onto the ground. This is unsatisfactory and can lead to damp, localised flooding and in some cases structural defects. This arrangement should be improved
Button: Downpipes To Ground - Right Side
Text: The rainwater downpipe to the right side elevation discharges directly onto the ground. This is unsatisfactory and can lead to damp, localised flooding and in some cases structural defects. This arrangement should be improved
Button: Gullies Damaged - Multiple
Text: Some of the gullies are damaged. Repair or replace
Button: Gulley Damaged - Front
Text: The front gulley is damaged. Repair or replace
Button: Gulley Damaged - Rear
Text: The rear gulley is damaged. Repair or replace
Button: Gulley Damaged - Left Side
Text: The left side gulley is damaged. Repair or replace
Button: Gulley Damaged - Right Side
Text: The right side gulley is damaged. Repair or replace
Garages Defects
Button: Dilapidated Garage - Asbestos Cement
Text: The asbestos cement garage is old and is in a poor state of repair and I recommend it is removed. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken
Button: Dilapidated Garage - Prefabricated
Text: The prefabricated garage is old and is in a poor state of repair and I recommend it is removed
Button: Structural Movement to Garage - Further Investigation
Text: There is evidence of structural movement to the garage and further investigation by a Structural Engineer should be undertaken
Button: Asbestos Roof Sheets - Damaged
Text: The asbestos cement roof sheets are damaged and need to be replaced. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken
Button: Garage - Damaged Glazing
Text: Glazing to the garage is damaged. To reduce the risk of injury the defective glazing should be replaced
Button: Garage - Replace Roof
Text: The roof is in poor condition and needs replacing
Button: Garage - Leaking Roof Repair
Text: The garage roof appears to be leaking. The roof requires repair
Button: Garage - Woodworm
Text: There is evidence of infestation by wood boring beetles (commonly known as woodworm) within the garage. You should check whether there has been any previous treatment. If there is no evidence of this, you should have the timbers treated by a member of the Property Care Association
Button: Garage - Flashings Poor
Text: The flashings to the garage roof are poor and need to be repaired or replaced
Button: Garage - Damp
Text: There is evidence of damp in the garage. Repairs and improvements are required
Button: Garage - Damp & Mould
Text: There is evidence of damp and mould. Repairs and improvements are required
Button: Garage - Rainwater Leaking Causing Damp
Text: The leaking rainwater goods are causing dampness internally and should be repaired as a matter of urgency
Button: Garage - Rainwater Missing Causing Damp
Text: The missing rainwater goods are causing dampness internally and should be repaired as a matter of urgency
Button: Garage - Fire Door Inadequate
Text: Fire protection between the attached garage and main building is inadequate and improvements are needed to the interconnecting door
Button: Garage - Rotten Joinery
Text: Rotten joinery was noted to the garage and repairs are required
Button: Garage - Defective Door
Text: The door to the garage is defective and repairs are required
Button: Garage - Cracking To Floor
Text: Cracking was noted to the garage floor and repairs are required
Button: Garage - Flat Roof No Solar Protection
Text: The garage roof covering is not protected from the sun's harmful rays which could lead to premature deterioration and failure. Improvements are required
Button: Garage - Moss/Lichen To Roof
Text: Vegetation is growing on the surface of the roof reducing water run off which in turn will affect performance of the coverings. It should be carefully removed where build up is occurring
Button: Garage - Rainwater Leaking No Damp
Text: Some gutters are leaking and repairs are required to prevent flooding and dampness
Button: Garage - Rainwater Missing No Damp
Text: Some gutters are missing and repairs are required to prevent flooding and dampness
Outbuildings Defects
Button: Outbuilding - Asbestos Cement Poor Condition
Text: The asbestos cement outbuilding is old and is in a poor state of repair and I recommend it is removed. Before commencing any work on suspected asbestos containing materials a risk assessment should be undertaken
Button: Outbuilding - Prefabricated - Remove
Text: The prefabricated outbuilding is old and is in a poor state of repair and I recommend it is removed
Button: Outbuilding - Poor - Remove
Text: The outbuilding is old and is in a poor state of repair and I recommend it is removed
Button: Outbuilding - Movement
Text: There is evidence of structural movement to the outbuilding and further investigation by a Structural Engineer should be undertaken
Button: Outbuilding - Unsafe Glazing
Text: Glazing to the outbuilding is broken and should be replaced
Button: Outbuilding - Roof Poor - Repair
Text: The outbuilding roof is in poor condition and should be repaired
Button: Outbuilding - Roof - Leaking Repair
Text: The outbuilding roof appears to be leaking and should be repaired
Button: Outbuilding Roof - End of Life - Replace
Text: The outbuilding roof is at the end of its life expectancy and should be replaced
Button: Outbuilding - Beetle
Text: Evidence of wood boring beetles (woodworm) was noted to the outbuilding. You should check whether the timbers have been treated under a guarantee. If there is no evidence of this you should have all affected timbers treated by a member of the Property Care Association or similar
Button: Outbuilding - No Solar Protection
Text: The outbuilding roof covering is not protected from the suns harmful rays which could lead to premature deterioration and failure. Improvements are required
Button: Outbuilding - Rotten Joinery
Text: Rotten joinery was noted to the outbuilding and repairs are required
Button: Outbuilding - Defective Door
Text: The door to the garage is defective and repairs are required
Button: Outbuilding - Cracking To Floor
Text: Cracking was noted to the outbuilding floor and repairs are required
Button: Outbuilding - Moss/Lichen To Roof
Text: Vegetation is growing on the surface of the roof reducing water run off which in turn will affect performance of the coverings. It should be carefully removed where build up is occurring
Button: Outbuilding - Rainwater Leaking No Damp
Text: Some gutters to the outbuilding are leaking and repairs are required to prevent flooding and dampness
Button: Garage - Rainwater Missing No Damp