Roofs Notes
Button: Main Roof Replaced Check Consents
Text: The main roof coverings have been renewed. You should ensure that the replacement works comply with any relevant Local Authority consents or Building Regulations
Button: Main Roof Possible Asbestos
Text: The main roof coverings comprise artificial slates, which may contain asbestos. As there is a potential health and safety risk, a suitable risk assessment should be completed prior to any works being undertaken
Button: Extension Roof Possible Asbestos
Text: The extension roof coverings comprise artificial slates, which may contain asbestos. As there is a potential health and safety risk, a suitable risk assessment should be completed prior to any works being undertaken
Button: Mortar Fillets Warning
Text: The mortar fillets at the roof abutments are currently serviceable, but this type of detail has a limited life expectancy and is susceptible to cracking and water ingress as it weathers
Button: Pressure Washing Warning
Text: Evidence suggests that the roof coverings have been pressure washed. Although this method is commonly used to remove moss accumulation, it can also strip the protective surface of the coverings, thereby shortening their remaining lifespan
Button: Coverings Nearing End of Life
Text: The roof coverings are nearing the end of their serviceable life. Continued repair will be necessary in the short term until full renewal is carried out. It is recommended that quotations for replacement are obtained now to plan for future expenditure